INSTALLING AND CONFIGURING THE
PIR DETECTORS
1. Undo and remove the fixing screw from the
bottom edge of the PIR Detector, (keep the
screw safe for later). Carefully pull the bottom
edge of the detector away from the rear cover
and then slide down to release the top clips.
2. Carefully drill out the required mounting holes in
the rear cover using a 3mm drill according to
whether the unit is being mounted in a corner or
against a flat wall.
3. Using the rear cover as a template, mark the
positions of the fixing holes on the wall.
4. Fix the rear cover to the wall using the two
18mm No.4 screws and 22mm wall plugs,
(a 5mm hole will be required for the wall plugs).
Do not over-tighten the screws as this may
distort or damage the cover.
Note: The wall plugs supplied with the product
are not suitable for plasterboard walls, if
mounting the Detector onto plasterboard use
appropriate wall plugs.
5. To select the required sensitivity, set switch SW3
as follows:
UP HIGH sensitivity
DOWN LOW sensitivity
Note: The recommended setting is HIGH.
However, in cases of extreme environmental
problems or if unexplained false alarms are
experienced, it may be necessary to set the
sensitivity to LOW. Setting the device to LOW
sensitivity will require a greater amount of
movement in order to trigger the device.
6. Connect the PP3 Alkaline battery to the battery
clip. The LED behind the lens will rapidly flash
for approximately 2-3 minutes until the PIR has
stabilised. The LED will then stop flashing and
turn OFF.
TESTING A PIR DETECTOR
INDEPENDENTLY
7. Ensure that the LED indicator has stopped
flashing rapidly.
8. The ‘Test Mode’ button (SW1) is used to put
the PIR Detector into Walk Test Mode, which
overrides the 2 minute sleep period and allows
the operation of the detector to be checked
during installation. Press and hold the button
for 2 seconds to activate Test Mode for a fixed
5 minute after which it will automatically revert
to normal operation.
15
Rear Cover
Fixing
Screw
Rear Cover
Flat Wall
Mounting
Corner Wall
Mounting
Fixing
Screw
SW2 (Tamper)
SW1 (Test Mode)
SW3
S
e
n
s
it
iv
it
y
H
i
L
o
w
S
W
1
T
e
s
t
M
o
d
e
S
W
2
SW3 (Sensitivity)
SW3 up
High Sensitivity
SW3
Sensitivity
Hi
Low
SW3
Sensitivity
Hi
Low
SW3 down
Low Sensitivity
Zobrazit stránku 14