The Control Panel incorporates a terminal block for
connection of a Hard-wired Siren. The connection
terminal block is located inside the Control Panel
behind the front cover. To access the terminal block
you must first put the system into Test Mode to
prevent an alarm occurring.
To do this:
Press
The Arm and Part-Arm LEDs will flash.
Undo the two fixing screws on the top edge of the
Control Panel and open the front cover.
Before making any connections, ensure that the
Reset Jumper Link P1 is in the OFFposition and
then remove the DC power jack and disconnect 1
of the back-up batteries.
The tamper switches should be volt free and
normally closed, with the contacts opening in order
to trigger an alarm.
Note: The External Tamper Switch jumper link P51
should be fitted into the ON position only if the
hardwired tamper circuit is used, otherwise it must
be in the OFF position.
After making your external connections reconnect
the power supply and back-up Battery. Then close
the Control Panel cover and tighten the fixing
screws on the top edge.
EXTERNAL CONNECTIONS
Permanent
12Vdc power
supply output
(100mA max.)
V+
GND
Not used
GND
B+
GND
TAMP
Switched
12Vdc output
for wired Siren
(300mA max.)
GND
OUT
Tamper circuit
connections
for wired Siren
Normally closed
tamper contact
Hardwired
Siren
Terminal Block
External Tamper
Switch Jumper
Link P51
Reset Jumper
Link P1
TAMP GND B+ GND GND V+ OUT GND
TERMINAL
BLOCK DETAIL
OFF ON
Jumper Link
Reset Jumper Link P1
Jumper
L
ink
1
4
23
ENTER
, ,
User Access Code