12
7. Ensure that the Reset Jumper Link (P1) and the
External Tamper Switch Jumper Link (P51) are
set in the OFF position.
8. Connect battery leads to both back-up batteries
and refit batteries.
LEFT Battery: Red lead to the Red (
+
) battery
terminal
Black lead to the Black (
-
) battery
terminal
RIGHT Battery: Red lead to the Red (
+
) battery
terminal
Black lead to the Black (
-
) battery
terminal
Note: The Power LED may flash to indicate that
the unit is being operated from the back-up
batteries and that mains supply is not present.
9. If fitted, remove the plastic film covering the LCD
display and on the display window on the cover.
10. Close the lid of the Control Panel and fasten the
cover fixing screws.
11. Plug in and switch ON the Power Supply
Adaptor, (the Power LED should illuminate).
12. If required, connect the Control Panel to the
telephone line using the cable supplied by
inserting the small RJ11 plug into socket marked
LINE located on the bottom edge of the Control
Panel. If the cable supplied is not long enough
to reach a suitable phone point then it will need
extending using a coupler and extension lead
(not supplied).
LINKING A REMOTE CONTROL OR
REMOTE KEYPAD TO THE
CONTROL PANEL
If there are already 6 Remote Controls/Keypads
linked to the Control Panel then it will not be possible
to link any more. Attempting to learn a 7th device
will cause the panel to produce a single long beep
and display ‘Cannot Learn - System Full’ message
on screen for 3 seconds.
With unit in Standby mode (Power LED only
illuminated).
1. Press
This puts the Control Panel into Programming
Mode.
‘1. USER SETUP’ will be displayed.
2. Use the and buttons to scroll through
the menu until ‘2. SYSTEM SETUP’ is displayed
and press . ‘2-1 Remotes’ will be displayed.
3. Press again.
The number of Remote Controls/Keypads
already linked will be shown, (e.g. if there are
two Remotes Controls and one Remote Keypad
linked the display will show ‘2.1 Remotes = 3’).
The new Remote Control/Keypad can be programmed
as follows:
4. Press .
O. GND V+ OUT GND