4.
Fit the top keyhole slots of the mounting plate over
the screw heads. Remove the mounting plate and
adjust the screws until they form a neat fit with the
mounting plate with minimal movement.
5. Secure the mounting plate in position using the
two 25mm fixing screws in the bottom fixing holes.
6. Ensure that the Solar Siren main configuration
switch on the LED indicator board is set to
"SIREN" for use with this alarm system.
7. Undo the 3 screws holding the DIP Switch Cover
in place and remove the cover.
8. Under the cover you will find a series of 9 DIP
switches.
Note: When the Solar Siren is viewed as shown
above (Solar panel at top) the DIP switches are
‘upside down’.
9. DIP switches 1-8 are used to set the House
Code for the Siren and must be set to the same
ON/OFF combination as all other system devices.
10.
If required the maximum length of time that the
External Solar Siren will sound for when activated
under an alarm condition may be limited to 3
minutes using DIP switch 9 as follows:
ON as Control Panel setting
OFF 3 minutes
11
. The Solar Siren will acknowledge Disarm signals
from the Remote Control and Service Mode
signals by beeping. It is possible to disable these
acknowledgement beeps if required by removing
the jumper link P2 on the circuit board.
P2 fitted beep enabled
P2 removed beep disabled
12
. If for any reason you need to disable the Siren,
remove jumper link P3 on the circuit board. This
will prevent the Siren from sounding during an
alarm condition. However, the Siren will still beep
to acknowledge signals from the Remote Control,
(provided the beep feature is not disabled).
P3 fitted Siren enabled
P3 removed Siren disabled
13
.
To enable the Jamming Detect feature in the Solar
Siren fit the jumper link taped to the cover of the Siren
control unit across link pins P1 on the circuit board.
P1 fitted Jamming Detection enabled
P1 removed Jamming Detection disabled
14
. Refit the DIP switch cover and replace the three
cover fixing screws. Do not over tighten the screw
as this could damage the thread.
INSTALLATION
Tamper
switch
6 Volt 1.2Ahr
rechargeable
battery
9 Volt PP3 initial
power up battery
Siren
Printed circuit
board enclosure
Receiver
Aerial
DIP switch
cover
Alarm duration
DIP switch 9
House Code
DIP switches 1-8
7.5 Volt DC
charging adaptor
input
Front cover
locating tabs
Beep Disable Lin
k
Siren Disable Link
Jamming
Detection Link
LED Indicator PCB
Solar Panel
C.U.
Main Configuration Switch
(in SIREN Position)
SIREN
C.U. SIREN
P1
P2
P3
ON
1 2 3 4 5 6 7 8 9
Alarm Duration DIP switch 9
(Always change from the factory setting)
House Code
Main Configuration Switc
h
(in SIREN Position)
C.U. SIREN
18 SA5
Inside view of Solar Siren with exploded view under set-up panel