OPERATION
38 SA5
When leaving the premises, the system must be
Armed. However, before doing so, check that all
windows are closed and locked, all protected doors
are closed and PIR Movement Detectors are not
obstructed. Ensure that pets are restricted to areas
not protected by PIR Movement Detectors.
The system has three arming modes, ARM, Part-Arm
1 and Part-Arm 2. The Part-Arm modes allow for
selected zones to be left in a Disarmed state whilst the
remainder of the system is Armed.
When the system is Armed the mode being activated
will be displayed on the screen followed by the status
of the Latch Key feature. The programmed system
exit-delay will be displayed and counted don on the
screen. If exit-delay beeps are enabled the panel will
beep with the beep rate increasing in steps as the
exit-delay expires. At the end of the Exit period all
active zones will be fully Armed. By this time the
user must have left the property and closed the final
protected door.
If while the system is armed a detector on an active
zone is triggered the programmed entry-delay for that
zone will be displayed and counted down on the
screen. If entry-delay beeps are enabled the panel will
beep with the beep rate increasing in steps as the
entry-delay expires. If the system has not been
Disarmed when the entry-delay expires a Full Alarm
will occur. (Note: if the entry-delay for the zone
triggering the alarm is disabled then an alarm will
occur immediately the detector is triggered). Details
of the zone event that triggered the alarm will be
recorded in the Event-Log.
At the end of the programmed alarm duration the Siren
and Control Panel alarms will stop and the system will
automatically re-Arm itself, (subject to the conditions
of the Zone Lockout feature.
Notes: - To conserve power and maximise battery
life the PIR detector will only detect
movement if there has been no movement
detected within the previous 2 minutes.
- If the External Solar Siren is fitted and the 3
minute limit is enabled then the external
siren will shut down when the programmed
alarm duration expires or after 3 minutes,
whichever occurs first.
Voice Dialler
If an alarm condition occurs and the Voice dialler is
activated then the first enabled phone number in the
dialling sequence will be called and the recorded
alarm message will be replayed for the programmed
“Play Time” period. The recipient should acknowledge
the message by pressing the button on their
telephone keypad to shut down the dialler. If an
acknowledgment signal is not received, then the next
enabled number in the call sequence will be called. The
dialler will continue calling each enabled number in turn
until either all numbers in the sequence have been
dialled the set number of times or the dialling sequence
is cancelled by an acknowledged signal from a recipient.
ARMING THE SYSTEM
The system can be set in FULL ARM mode using either
the Remote Control or the Control Panel as follows:
a) Press on the Remote Control, or
b) Press
, ,
on the Control Panel.
PART ARMING THE SYSTEM:
PART-ARM 1
The system can be set in PART-ARM 1 mode using either
the Remote Control or the Control Panel as follows:
a) Press on the Remote Control, or
b) Press
, ,
on the Control Panel.
PART ARMING THE SYSTEM:
PART-ARM 2
The system can be set in PART-ARM 2 mode using either
the Remote Control or the Control Panel as follows:
a) Press , on the Remote Control,
or
OPERATING INSTRUCTIONS