Response SL5 Provozní pokyny Strana 35

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 34
PROGRAMMING
SA5
33
ENTRY-DELAY BEEPS
Allows the entry-delay warning beeps when activating
Full Arm to be switched ON or OFF.
Default Setting: ON
Scroll through the menu until ‘5-2 Entry Delay Beep’
(and the current setting) is displayed.
To change the setting press .
Press to enable the beeps, or
Press to disable the beeps.
EXIT-DELAY BEEPS
Allows the exit-delay warning beeps when activating
Full Arm to be switched ON or OFF.
Default Setting: ON
Scroll through the menu until ‘5-3 Exit Delay Beep’
(and the current setting) is displayed.
To change the setting press .
Enter the required number of dial attempts (1-5).
Press to enable the beeps, or
Press to disable the beeps.
PART-ARM 1 SETUP
The parameters in this menu control over the systems
exit-delay period and the exit/entry delay warning
beeps during Part-Arm 1 mode.
Scroll through the programming menu until ‘6. PART
ARM 1 SETUP’ is displayed and press .
Note: After configuring Full Arm press to
return to the top level programming menu.
EXIT-DELAY PERIOD
Scroll through the menu until ‘6-1 EXIT-DELAY’ (and
the current setting) is displayed
.
To change the settings press .
On/Off Status
Default setting: ON
Scroll through the menu until ‘6-1-1 Status’ (and
the current setting) is displayed.
To change the setting press .
Press to enable the exit-delay, or
Press to disable the exit-delay.
Delay Period
Default setting: 30s
Scroll through the menu until ‘6-1-2 Delay Time’
(and the current setting) is displayed.
To change the settings press .
Enter the required delay period (10 to 250s).
Press to save and exit, or
Press to exit without saving.
Press to return to top level Part-Arm 1
Setup menu.
EXIT-DELAY BEEPS
Allows the entry-delay warning beeps when activating
Part-Arm 1 to be switched ON or OFF.
Default Setting: ON
Scroll through the menu until ‘6-2 Entry Delay Beep’
(and the current setting) is displayed.
To change the setting press .
Press to enable the beeps, or
Press to disable the beeps.
6. PART ARM 1
SETUP
PROGRAM MODE
Code:
6-3 Exit Delay
Beep: xxx
6-2 Entry Delay
Beep: xxx
Select
ON->1 OFF->3
Select
ON->1 OFF->3
6-1 EXIT Delay
xxx xxxs
6-1-1 Status
xxx
Select
ON->1 OFF->3
6-1-2 Delay Time
Enter (10-250s)
Enter (10-250s)
1
3
1
3
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
1
3
ENTER
ENTER
ESC
ESC
ENTER
ESC
ESC
Zobrazit stránku 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 51 52

Komentáře k této Příručce

Žádné komentáře